FR1 SPECIFICATION

NO

ITEM

UNIT

VALUE

1

RESISTANCE OF THE COPPER FOIL 35uM

CM

MAX:3.5

2

VOLUME RESISTIVITY

AT NORMAL CONDITION:

AFTER RECOVERY THROUGH STEADY HEAT/HUMIDITY TREATMENT:

CM

MIN: 5.0*1011

3

SURFACE RESISTANCE ON ETCHED COPPER FOIL SIDE

AT NORMAL CONDITION:

AFTER RECOVERY THROUGH STEADY HEAT/HUMIDITY TREATMENT:

 

 

MIN: 1.0*1011

 

MIN: 1.0*1010

4

SURFACE RESISTANCE ON THE LAMINATE

AT NORMAL CONDITION:

AFTER RECOVERY THROUGH STEADY HEAT/HUMIDITY TREATMENT:

 

 

MIN: 1.0*1010

 

MIN: 1.0*108

5

INSULATING RESISTANCE

AT NORMAL CONDITION:

AFTER BOILING IN WATER:

 

MIN: 1.0*1011

MIN: 5.0*107

6

(1MHZ)PERMITIVITY

AT NORMAL CONDITION:

AFTER IMMERSDING IN WATER:

 

 

MAX: 5.3

MAX: 5.8

7

(1MHZ)DIELECTRIC DISSIPATION FACTOR

AT NORMAL CONDITION:

AFTER IMMERSDING IN WATER:

 

 

 

MAX: 0.045

MAX: 0.065

8

PEEL STRENGTH

AT NORMAL CONDITION

AFTER 5S HEAT STOCK

N/MM

MIN: 1.2

9

BLISTERING AFTER 10S HEAT STOCK

 

NO BLISTER OR DELAMINATION

10

PUNCHING PROPERTY

5/4/4

COLD PUNCH

11

HEATPROOF AT 130+/-2, FOR 60MIN

 

NO BLISTER OR DELAMINATION

12

FLEXURAL STRENGTH

MPA

MIN: 100

13

TRICHLOROETHYLEN AND ALKALI RESISTANCE

 

APPERENCE NO OBVIOUS VARIETY

14

FALLING BALL IMPACT

CM

MIN: 4.5

15

WATER ABSORPTION

%

MAX: 1.2

16

FLAMMABILITY            VERTICAL

 

FV0